翻訳と辞書
Words near each other
・ Lateral cutaneous branch of iliohypogastric nerve
・ Lateral cutaneous nerve
・ Lateral cutaneous nerve of arm
・ Lateral cutaneous nerve of forearm
・ Lateral cutaneous nerve of thigh
・ Lateral dorsal cutaneous nerve
・ Lateral dorsal nucleus of thalamus
・ Lateral earth pressure
・ Lateral electrical surface stimulation
・ Lateral epicondyle
・ Lateral epicondyle of the femur
・ Lateral epicondyle of the humerus
・ Lateral eruption
・ Lateral expansion
・ Lateral flap
Lateral flow test
・ Lateral force variation
・ Lateral funiculus
・ Lateral genicular artery
・ Lateral geniculate nucleus
・ Lateral giant interneuron
・ Lateral globus pallidus
・ Lateral grey column
・ Lateral horn
・ Lateral horn of insect brain
・ Lateral hypothalamus
・ Lateral inguinal fossa
・ Lateral inhibition
・ Lateral intermuscular septum
・ Lateral intermuscular septum of thigh


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Lateral flow test : ウィキペディア英語版
Lateral flow test

Lateral flow tests〔(Concurrent Engineering for Lateral-Flow Diagnostics (IVDT archive, Nov 99) )〕 also known as lateral flow immunochromatographic assays, are simple devices intended to detect the presence (or absence) of a target analyte in sample (matrix) without the need for specialized and costly equipment, though many lab based applications exist that are supported by reading equipment. Typically, these tests are used for medical diagnostics either for home testing, point of care testing, or laboratory use. A widely spread and well known application is the home pregnancy test.
The technology is based on a series of capillary beds, such as pieces of porous paper〔http://www.khufash.com/bd/applications/lateral_flow/lf_main_page.htm〕 or sintered polymer.〔http://www.porex.com/products/clinical-sciences/in-vitro-diagnostics/〕 Each of these elements has the capacity to transport fluid (e.g., urine) spontaneously. The first element (the sample pad) acts as a sponge and holds an excess of sample fluid. Once soaked, the fluid migrates to the second element (conjugate pad) in which the manufacturer has stored the so-called conjugate, a dried format of bio-active particles (see below) in a salt-sugar matrix that contains everything to guarantee an optimized chemical reaction between the target molecule (e.g., an antigen) and its chemical partner (e.g., antibody) that has been immobilized on the particle's surface. While the sample fluid dissolves the salt-sugar matrix, it also dissolves the particles and in one combined transport action the sample and conjugate mix while flowing through the porous structure. In this way, the analyte binds to the particles while migrating further through the third capillary bed. This material has one or more areas (often called stripes) where a third molecule has been immobilized by the manufacturer. By the time the sample-conjugate mix reaches these strips, analyte has been bound on the particle and the third 'capture' molecule binds the complex. After a while, when more and more fluid has passed the stripes, particles accumulate and the stripe-area changes color. Typically there are at least two stripes: one (the control) that captures any particle and thereby shows that reaction conditions and technology worked fine, the second contains a specific capture molecule and only captures those particles onto which an analyte molecule has been immobilized. After passing these reaction zones the fluid enters the final porous material, the wick, that simply acts as a waste container. Lateral Flow Tests can operate as either competitive or sandwich assays.
== Coloured particles ==
In principle, any coloured particle can be used, however latex (blue colour) or nanometer sized particles of gold (red colour) are most commonly used. The gold particles are red in colour due to localised surface plasmon resonance. Fluorescent〔((Point-of-Care Technologies) Developing rapid mobile POC systems - Part 1: Devices and applications for lateral-flow immunodiagnostics (IVDT archive, Jul 07) )〕 or magnetic〔(Paramagnetic-particle detection in lateral-flow assays (IVDT archive, Apr 02) )〕〔(Magnetic immunoassays: A new paradigm in POCT (IVDT archive, Jul/Aug 2008) )〕 labeled particles can also be used, however these require the use of an electronic reader to assess the test result.